Portable water analyzer
Model:CN63M/IIIS
Model:CN63M/IIISPower:<250 mWWorking volt:9V DCSize:200mm×100mm×40mmMain measure indicators
Measurement items Measuring range Resolution Accuracy emperature compensationtemperature(t) -5~+50℃ 0.1℃ ±0.3℃salinity(s) 0~40‰ 0.1‰ ±1.0‰ automaticDO(Do) 0~20mg/L 0.01mg/L ±0.3mg/L automaticpHValue 0~14 0.01pH ±0.05 automaticammonia(NH3) 10-1~10-5.3mol/L 0.01mg/L ±0.05 mg/L automaticsulfuerted hydrogen(H2S) 10-1~10-5.3mol/L 0.01 mg/L ±0.05 mg/L automatic
HardwareCN63M/IIIS portable water quality analyzer system includes the host hardware, sensors and accessories in three parts.Sensor (ie, electrode) part includes: the electrode temperature, salinity electrode, dissolved oxygen electrode, pH electrode, ammonia electrode, hydrogen electrode.Appendix section includes: power supply, electrode parts, operating instructions,Basic Manual, operation and demonstration CD, certificate and so on. ,Functions and characteristicsCN63M/IIIS portable analyzer to potential water quality analysis and conductivity analysis, based on the theory, and integrated use of electrochemical sensors, integrated electronics and microcontroller technology, aquaculture, environmental protection, sewage treatment in areas such as the ideal tool for water quality analysis , is the formation of water ideal for analytical chemistry laboratories. Functions: detection of water temperature, salinity, dissolved oxygen, pH, ammonia, hydrogen sulfideFeatures: Automatic detection, simple, reproducible, and stability, on-site monitoring, the appearance of light, AC and DCUse of equipmentDetection of Water AquacultureLaboratory equipmentSewage water quality testingDetection of industrial and agricultural water supply and drainageWater testingBoiler water testingIstrcuctionCN63M/IIIS multifunctional water quality analyzer easy to use instructions and precautions1 Start or install the battery power devices, press the red button to start the instrument.2. Apparatus for the measurement(A) temperature measurement instruments the temperature on the electrode connector into the corresponding socket (the socket marked T), the temperature of the electrode into the solution under test, press the measure key to measurements, stable value, or appear to be OK, press OKto end, press the Enter key to return to the main menu.(B) salinity measured the temperature corresponding to the electrode inserted into the socket on the instrument, the salinity of the electrode plug the jack marked with S, press the left or right button, move the cursor to the bottom of S, the temperature andsalinity electrodes are placed in the solution under test, press the measure key to measurements, the instrument will first temperature measurement, numerical stability and press OK key measure salinity, temperature data appears to be OK, or after the instrument to measure directly on the salinity.Salinity values to be stable, or appear OK, press the Enter key to end, press the OK button to return to the main menu.
(C) the temperature measurement of dissolved oxygen electrodes inserted into the corresponding socket on the instrument, the dissolved oxygen electrode plug the jack marked with the DO, press left or right button, move the cursor to the bottom DO, the temperature anddissolved oxygen electrodes are placed in the solution under test, measured by measuring key, gently shake the dissolved oxygen electrode, the instrument will first temperature measurement, numerical stability of dissolved oxygen measurement and press OK key, or value appears to be OK after the instrument temperaturemeasured directly on the dissolved oxygen, dissolved oxygen values to be stable, or appear OK, press the Enter key to end, return to the main menu.(D) PH measuring the temperature of the electrode into the instrument corresponding to outlet, PH electrode plug into the jack marked with the PX, press the left or right button, move the cursor to the bottom of PH, the temperature and the PH electrodeare put under test solution, according to the measure key to measurements, temperature measurement instruments will be numerical stable PH value measurement press the Enter key, or value appears to be OK after the temperature instrument to measure directly on the PH, PH value to bestable or there OK, press the Enter key to end, return to the main menu.(E) 50ml solution of ammonia measurements taken under test around the temperature corresponding to the electrode inserted into the socket on the instrument, the ammonia electrode plug into the jack marked with the PX, the ammonia electrode shell unscrewed, put two droppersammonia in liquid-filled, and then screw down and put it into distilled water or water, press left or right button, move the cursor to E below, press the button to wash the blank measurement potential, more potential value to 50mv, press the Enter key, appears OK, then press OK button to return to the main menu to remove the ammonia electrode, dried with filter paper, the temperature and ammonia electrodes are placed under test solution, in the tested solution with a dropper to add 4 to 5 drops of ammonia buffer solution (10M/ LNaOH solution), stir, move the cursor to the bottom of NH3, press the measure key to measurements, the instrument will first temperature measurement, numerical stability of ammonia measurement and press OK key value, or value appears to be OK after the temperature of the instrument will directlyammonia measured values to be stable ammonia or there OK, press the Enter key to end, return to the main menu.After the ammonia electrode measurement can be placed in distilled water or water potential in the space allowed to self-cleaning (no need to use equipment cleaning), so you can use, will not have to re-wash before use blank potential.(F) Hydrogen sulfide measurements taken around 50ml solution under test, the temperature of the electrode into the corresponding socket on the instrument, the hydrogen sulfide electrode PX plug into the jack marked on the shell of the hydrogen sulfide unscrew the electrode, into thedropper filled within two hydrogen sulfide, and then screw down and put it into distilled water or water, press the left or right button, move the cursor to E below, press the button to wash the blank measurement potential, the potential value reached after the above-200mv, press the Enter key, appears OK, then OK button to return to the main menu, to remove hydrogen sulfide electrode, dried with filter paper, the temperature and hydrogen sulfide electrodes are placed under test solution, with a dropper to add in the tested solution4 to 5 drops of liquid hydrogen sulfide slow adjustment (10M/LNaOH solution), stir, press the left or right button, move the cursor to the bottom of H2S, press the measure key to measurements, the instrument will first temperature measurement, numerical stabilitymeasurement of hydrogen sulfide and press OK key value, or value appears to be OK after the temperature instrument to measure directly on the hydrogen sulfide, hydrogen sulfide to be numerically stable and press OK key to end, return to the main menu.Hydrogen sulfide can be measured after the electrode into the distilled water or water potential in the space allowed to self-cleaning (no need to use equipment cleaning), so you can use, will not have to re-wash before use blank potential.
Notes(A) of the dropper can not be mixed, a solution can only be used for each pipette, or dropper clean after use.(B) the salinity of the electrode into the water after use save as much as possible.(C) PH electrode should be placed after use with the protection of its original solution to save, when used in its attention to the protective solution for safe place to prevent accidentally knocked over.(D) of ammonia and hydrogen sulfide electrode must be added prior to use and clean filling gaps within the potential, otherwise it would be inaccurate values.(E) dissolved oxygen membrane electrode should pay attention to the protection, do not let the tip hit a hard object not to touch the membrane oxygen the oxygen membrane.After use the electrode into the water as far as possible preserved, and its surface membrane can be no more than just peroxide solder joints at the oxygen electrode.(F) electrode should be cleaned after use, then dry with filter paper electrode in accordance with the requirements of each save.(G) ammonia and hydrogen sulfide electrode are both filled dropper dosage (volume inhaled per dropper dropper total capacity of about 1 / 3 can).(H) ammonia and hydrogen sulfide potential of the electrode gap when cleaning the electrode in distilled water or water in the rapid rise in the value of shaking the potential to save time
Note: The instrument calibration and details, please see instructions. |
|
|
|
|
Additional photos

|
|
|
|
|
Company Information
(Midwest Group) |
|
Company Profile: |
Midwest Group is one of the largest manufacturer and supplier of measuring and electrical instruments and equipments as well as high tech products in China, which has been engaged in these fields since 1988 with about 1,000,000 kinds of products. It is an enterprise group that integrated with manufacturing, technology development, international trade, engineering consulting and maintenance services. There are many offices, joint ventures, and subsidiary companies both home and abroad. We insist on the policy that seeking development through new and high technology and constantly cooperate with domestic and international manufacturers and with scientific research institutions. Our products spread all over the world with strong capability, good prestige, fine quality, rational price and thoughtful service. The products are applied to the fields of environmental protection, chemical industry, petroleum, steel, papermaking, electricity, metallurgy, machinery, coking, pharmacy, optics, communication, scientific and technological education, medical and health. We can not only offer customer the most extensive products option in the aspects of product character and price, but also offer users scientific and technological information swiftly. We have specialized technical staff and research department, offer Omni-directional services to customer, such as consultation, training, after-sale service and maintenance.. >> More |
|
Website URL: |
http://www.bridgat.com/u37205 |
|
|
Contact Information |
|
Mailing Address: |
No.1,3rd,Shangdi,Haidian District Beijing Beijing 100085 |
|
Country: |
China
|
|
Phone Number: |
+86-010-13530289768 |
|
Fax Number: |
|
|
Contact person: |
Miss Cherry Lin- Send Email Now! |
|
|
|
|
|
|
|
|
|
|
|
Latest Buying Listings
|
|
|
|
|
|
|
Welcome, guest !
We have 0 members
and 163 guests
online
|
|
|