DIN 5510-2/DIN5510-2 Preventive fire protection in Railway vehicles
Firetc fire test center will provide Germany Standard DIN 5510-2 Fire test to Railway vehicles.
For more detailed information about DIN 5510-2
Please see: http://www.firetc.net/firetesting/show.php?itemid=658
DIN 5510-2 Fire test to railway components-Standard
> DIN5510-2 Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
DIN 5510-2 Fire test to railway components-Introduction
DIN 5510-2 determinate the fire classification of railway vehicle material and structure by burning behaviour, smoke density, dropping behavieour and toxic
DIN 5510-2 Fire test to railway component - Products Scope
DIN 5510-2 is acceptable to all train, railway vehicle, metro defined in EBO, ESBO, BOStrab
Fire test to railway components--small parts (handle, AD panel)
> Test Method: DIN 53438--Testing of combustible materials; response to ignition by a small flame
> Classification: S1
Fire test to railway components-structure(seal, flooring, wall)
> Test Method: DIN 54837 - Testing of materials, small components and component sections for rail vehicles - Determination of burning behaviour using a gas burner
> Classification: S2-S5, ST1-ST2, SR1-SR2
Fire test to railway components - flooring(including adhesive and glue
> Test Method: ISO 9239-1 Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
> Classification: SF1-SF3
Fire test to railway components - Seat
> Test Method:DIN 5510-2, DIN EN 1021-1 and DIN EN 1021-2
Fire test to railway components – Electrical device
> Test Method:EN 60695
Fire test to railway components--Cable & Wire
> DIN EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions
> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions
>DIN EN 61034-2 Measurement of smoke density of cables burning under defined conditions
Smoke toxic test according new version DIN 5510-2:2009:05, DIN EN ISO 5659-2, Smoke toxic test (toxicity measured with FTIR):FED DIN 4102-1: fire behaviour of building materials and elements – Part 1: classification of building materials - requirements and testing
> DIN 4102-8: Fire behaviour of building materials and components - Part 8: Small scale test furnace
> DIN 5510-1: Preventive fire protection in railway vehicles - Part 1: levels of protection. fire preventive measures
> DIN 5510-4: Preventive fire protection in railway vehicles - Part 4: vehicle design; safety requirements
> DIN 5510-5: Preventive fire protection in railway vehicles – Part 5: electrical equipment; safety requirements
> DIN 5510-6: Preventive fire protection in railway vehicles – Part 6: auxiliary measures. emergency brake operating function; information systems. fire alarms. fire fighting equipment; safety requirements
> DIN 53438-1 Testing of combustible materials; response to ignition by a small flame; general data
> DIN 53438-2 Testing of combustible materials; response to ignition by a small flame; edge ignition
> DIN 53438-3 Testing of combustible materials; response to ignition by a small flame; surface ignition
> DIN 54341: Testing of seats in railways for public traffic; determination of burning behaviour with a paper pillow ignition source
> DIN 54837: Testing of materials, small components and component sections for rail vehicles - Determination of burning behaviour using a gas burner
> DIN EN 597-1:Furniture. Assessment of the ignitability of mattresses and upholstered bed bases. Ignition source: smouldering cigarette
> DIN EN 597-2:Furniture. Assessment of the ignitability of mattresses and upholstered bed bases. Ignition source: match flame equivalent
> DIN 1021-1: Furniture - Assessment of the ignitability of upholstered furniture - Part 1: Ignition source smouldering cigarette
> DIN 1021-2: Furniture - Assessment of the ignitability of upholstered furniture - Part 2: Ignition source match flame equivalent
> DIN EN 13501-1: Fire classification of construction products and building elements. Classification using test data from reaction to fire tests
> DIN EN 13501-2: Fire classification of construction products and building elements. Classification using data from fire resistance tests, excluding ventilation services
> DIN EN 14390:Fire test - Large-scale room reference test for surface products
> E DIN EN 45545-2:Railway applications. Fire protection on railway vehicles. Part 2. Requirements for fire behaviour of materials and components
> DIN EN 50264-1: Railway applications - Railway rolling stock cables having special fire performance; Standard wall - Part 1: General requirements
> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C
> DIN EN 50266-2-5 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-5: procedures – Category D
> DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods
> DIN EN 50306-1: Railway applications - Railway rolling stock cables having special fire performances - Thin wall - Part 1: General requirements
> DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
> DIN EN 60332-2-2 Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame;
> DIN 60695-11-10: Fire hazard testing. Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
> DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus.
> DIN EN ISO 4589-2: Plastics - Determination of burning behaviour by oxygen index -- Part 2: Ambient-temperature test
> DIN EN ISO 5659-2: Smoke generation -- Part 2: Determination of optical density by a single-chamber test
> DIN EN ISO 9239-1: Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
For more detailed information about Germany Standard DIN 5510-2 fire test to Railway Components. Please contact on firetest@firetc.com.
Learn more from www.firetc.net for English or www.firetc.com for Chinese |
|
|
|
|
Additional photos

|
|
|
|
|
Company Information
(Firetc Fire Test Center) |
|
Company Profile: |
Firetc fire test center work with Ecosafene(www.ecosafene.com) and Crepim(www.crepim.org) and will conduct kinds of fire test for Building material, railway components, marine equipment, aircraft material, motor vehicle and furniture, the test method involve: GB20286, GB8624, BS476-6, EN45545-2,NFF16-101, DIN5510-2, NFPA130,BS6853, NFP92-501, DIN4102, EN13501-1,FAR25.853, UL94, ASTME162, ASTME662, BS476-22, EN1363-1, AS1530… FIRETC is a B2B electronic Business website for Fire Resource. And it is dedicated to providing a platform for miscellaneous communication and collaboration among the manufacturers, traders, and purchasing agents in industry of flame retarding, fire proof, fire resistance. FIRETC is an information center for worldwide fire regulation and standard and flame retardant knowledge, which aim for increasing the attention for fire and avoiding fire. FIRETC will provide more special platform and create more business chance to manufactures and traders who work for fire precaution, fire protection and fire safety Firetc fire test center work with Ecosafene(www.ecosafene.com) and Crepim(www.crepim.org) and can Our Aim: Make people understand fire from fire standard and regulation and away from fire Help manufacture and trader to avoid technical trade barrier of fire Establish a active business center for manufacturer, trader and researcher. Our Value: Precaution, Protection and Safety Away from fire, protect our life and property.. >> More |
|
Website URL: |
http://www.bridgat.com/u52846 |
|
|
Contact Information |
|
Mailing Address: |
Powercenter, No.301 Jiahe Road Xiamen Fujian 364012 |
|
Country: |
Germany
|
|
Phone Number: |
+86-0592-5056213 |
|
Fax Number: |
+86-0592-5105807 |
|
Contact person: |
Mr Gong Liu- Send Email Now! |
|
|
|
|
|
|
|
|
|
|
|
Latest Buying Listings
|
|
|
|
|
|
|
Welcome, guest !
We have 0 members
and 276 guests
online
|
|
|